Selection Guide

Confirm operating conditions, match the application, then specify connections and power.

  1. 01

    Gas conditionsGas

    Gas typeFlow rangePressure range
  2. 02

    ApplicationApplication

    Equipment / PLCDesktop useComputerMultiple units
  3. 03

    Power & fittingsPower & fittings

    Gas fittingsPower supplySpecial needs
01

Operating conditions

1. Gas

Specify the gas name, or mixture composition and proportions. Choose a controller to regulate flow, or a meter to measure flow only.

2. Actual flow range

Provide minimum, typical and maximum operating flow with units. Convert the maximum to nitrogen-equivalent flow before selecting a range.

3. Pressure range

Specify inlet and outlet pressure ranges separately, including gauge or absolute pressure. Include vacuum, backpressure or fluctuations where applicable.

Select the series using nitrogen-equivalent flow

Nitrogen-equivalent flow = actual gas flow ÷ gas conversion factor

Example: 9 SLPM methane ÷ 0.719 ≈ 12.52 SLPM nitrogen-equivalent. Select the 803 series.

Read the conversion guide →
0–10 SLPM802 series
10–50 SLPM803 series
50–200 SLPM805 series
200–1000 SLPM807 series
02

Application

4. How will it be used?

After choosing the flow range, match the configuration to the control system and operation needs.

ApplicationSuggested configuration
Inside equipment, controlled by a PLC or DAQ card0–5V / 4–20mA analog interfaces: FL-xxx-A, or a digital model with suitable analog interfaces.
Multiple instrumentsRS485 / Modbus RTU for centralized reading and control.
Single-channel desktop operation with occasional adjustmentsFL-xxx-A + FL-100 for local setting and display.
Computer-based setting and readingFL-xxx-D with a DB9 communication cable, RS485-to-USB module and application control software.
Direct desktop operation plus computer connectionCM-xxxLD with built-in keys and LCD, plus computer connectivity.
Local operation at the equipment panelCM-xxxLD; confirm installation and interface requirements.

-A: analog interfaces. -D: RS485, Modbus RTU, 0–5V / 4–20mA. CM: integrated display. Meter models add -M to the corresponding model and provide measurement only.

03

Power & fittings

5. Gas fittings

Specify fitting type and tube size, such as 6mm or 1/4″ double-ferrule fittings, or 8mm hose fittings. Multiple sizes are available; tubing is not included in the standard configuration.

6. Power supply

Product supply: 9–36VDC, typically 24VDC. Use the equipment’s existing 24V supply or a separate power adapter. An FL-100 combination uses its matched instrument power arrangement.

7. Special requirements

Specify accuracy, materials, installation space, multi-channel integration, gas mixing or custom software requirements.